Synthes large frag inventory - 394.35 Large Distractor Reduce the fracture fragments and confirm reduction using image intensification. Note: Application of an external fixator or large distractor may facilitate visualization and reduction of the joint. Prior to plate application, reduction may be stabilized using independent K-wires or independent lag screws. When using

 
Synthes (USA) Synthes (Canada) Ltd. To Order: (800) 523-0322 To Order: (800) 668-1119 Date: Hospital: Surgeon: Procedure: Patient Information: Inventory Control Form Titanium 2.7 mm / 3.5 mm Variable Angle LCP Elbow System 04.107.002 2 holes, right 04.107.102 2 holes, left 2.7 mm / 3.5 mm Variable Angle LCP Proximal Olecranon Plates 04.107.202 .... Funny happy friday gifs

Like the weather, the housing market usually cools in the fall. Will the coronavirus make this year different? By clicking "TRY IT", I agree to receive newsletters and promotions f...Edit synthes large fragment set inventory sheet form. Text may be added and replaced, new objects can be included, pages can be rearranged, watermarks and page numbers can be added, and so on. When you're done editing, click Done and then go to the Documents tab to combine, divide, lock, or unlock the file.synthes.vo.llnwd.netFollow our simple steps to get your Synthes Large Frag Inventory ready quickly: Select the template from the library. Type all required information in the required fillable fields. The easy-to-use drag&drop interface makes it easy to add or move fields. Ensure everything is filled in properly, with no typos or lacking blocks.synthes.vo.llnwd.netSynthes LCP Modular Mini Fragment Instrument and Implant Set (01.111.120) 2.4 mm Locking Compression Plate Set Instruments and Storage Catalog # Description 314.467 StarDrive Screwdriver Shaft, T8, 105 mm 310.530 2.4 mm Drill Bit, Quick Coupling, 100 mm 310.509 1.8 mm Drill Bit With Depth Mark, Quick Coupling, 110 mm LengthThe sequential introduction of plating and screw technologies has led to a total number of more than 20 DePuy Synthes sets to support small fragment procedures involving shoulder, clavicle, elbow, tibia and fibula anatomies. Surgical treatment of small bone trauma occurs worldwide about every 18 seconds and represents about 25% of all bone ...SYNTHES (USA) SYNTHES (Canada) Ltd. To Order: (800) 523-0322 To Order: (800) 668-1119 Date: Hospital: Surgeon: Procedure: Implants Patient Information: J7889-C 2/12 …DePuy Synthes Inventory Control Form Small Fragment LCP System 2011; Get DePuy Synthes Inventory Control Form Small Fragment LCP System 2011-2024 Get form Show details. 119 Date: Hospital: Surgeon: Procedure: Implants 3.5 mm Shaft Screws 2.7 mm Cortex Screws, self-tapping LENGTH LENGTH 202.810 202.812 202.814 202.816 202.818 202.820 202.822 202 ...Inventory Control Form 4.5, 5.5, 6.5, 7.5 mm Cannulated Compression Headless Screws (CCHS) Implants The screws are made of titanium alloy (TAV) 30 mm 32 mm 34 mm 36 mm 38 mm 40 mm 42 mm 44 mm 46 mm 48 mm 50 mm 55 mm 60 mm 65 mm 70 mm 75 mm 80 mm 85 mm 90 mm 95 mm 100 mm 105 mm 110 mm LengthFor the DePuy Synthes VA-LCP and the Biomet plate, when monoaxial screws could not purchase the targeted fragment, we tried to apply the VA screw at an appropriate angulation. Different plates and different locations of raft screws showed their relatively high-frequency usage in a disparate range of angles (Figure 6). For the DePuy Synthes VA ...For the DePuy Synthes VA-LCP and the Biomet plate, when monoaxial screws could not purchase the targeted fragment, we tried to apply the VA screw at an appropriate angulation. Different plates and different locations of raft screws showed their relatively high-frequency usage in a disparate range of angles (Figure 6). For the DePuy Synthes VA ...Inventory Control Form QIS AND 2.0 MM CANNULATED SCREW SYSTEM PLUS (CSS+) Head Height: 1.65 mm Washer and Head Construct Height: 1.44 mm Thread Length Short Thread: approx. 25% Total Length or 4 mm Long Thread: approx. 40% Total Length Thread Length Head Height Construct Height Length Washers Part Number 04.353.900.05 Washer For 2.0 Cann Screw ...1 Inventory Control form mm, mm, mm and mm cannulated Screws Patient Information: Synthes (USA) Synthes (Canada) Ltd. To Order: (800) 523-0322 To Order: (800) 668-1119. Date: Hospital: Surgeon: Procedure: Implants mm cannulated Screws, mm cannulated Screws, partially threaded 16 mm thread length LENGTH LENGTH LENGTH LENGTH. 20 mm 46 mm 30 mm 100 mm 22 mm 48 mm 35 mm 105 mm 24 mm 50 mm 40 mm ...Inventory Control Form - synthes.vo.llnwd.net synthes.vo.llnwd.net. Implants Date: Hospital: Surgeon: Procedure: Case Information (eg, Case ID): Inventory Control Form Small Fragment Locking Compression Plate (LCP®) System 3.5 mm Locking Screws, self-tapping, with StarDriveTM Recess Form, Control, Inventory, Synthes, Inventory control form synthes, Inventory control formSynthes Small Fragment Instrument & Implant Set - LC-DCP, With Self Tapping Screws (145.445) Instrumentation Catalog # Description 292.12 1.25 mm K-Wire, 160 mm, Trocar Point (16) 292.16 1.6 mm K-Wire, 150 mm, Trocar Point (10) 292.20 2.0 mm K-Wire, 150 mm, Trocar Point (3) 310.25 2.5 mm Drill Bit, Quick Coupling, 110 mm, Gold (3)Synthes (USA) Synthes (Canada) Ltd. To Order: (800) 523-0322 To Order: (800) 668-1119 Date: Hospital: Surgeon: Procedure: Implants Instruments Patient Information: J9794-B 5/11 Inventory Control Form 3.5 mm LCP Periarticular Proximal Humerus Plates 3.5 mm LCP Periarticular Proximal Humerus Plates HOLES 02.123.020 2, right 02.123.021 2, left 02. ...synthes.vo.llnwd.netINVENTORY CONTROL FORM Tibial Nail Advanced System Implants To order (USA): 800-523-0322 To order (Canada): 844-243-4321 Date: Hospital: Surgeon: Procedure: Tibial Nail Advanced System B 8 mm, Sterile Tibial Nail Advanced System B 11 mm, Sterile Tibial Nail Advanced System B 9 mm, Sterile Tibial Nail Advanced System B 12 mm, SterileA-Z Ortho 917 Lone Oak Rd Eagan, MN 55121 [email protected] Call 800.524.5194 Proud to offer products made in the USA.In this study, atmospheric mercury emission inventory was estimated from various anthropogenic sources of emission in Tehran province, including stationary, mobile and also natural sources. The mercury emission factors from different sources were obtained using the United Nations Environment Programme, the United States Environmental Protection Agency AP-42 and related papers. Twelve mercury ...Large Diameter Guide Wires • To provide more precise screw placement. Low Profile Screw Head Reverse Cutting Flute • To facilitate removal. Packaging • Implants individually sterile packaged. Features & Benefits The Asnis III Cannulated Screw System is designed to assist surgical outcomes while simplifying procedures.SYNTHES (USA) SYNTHES (Canada) Ltd. To Order: (800) 523-0322 To Order: (800) 668-1119 ... Procedure: Implants Patient Information: J2850-J 9/12 Inventory Control Form Orthopaedic Cable System Cables with Crimp Stainless Steel Cerclage Buttons 298.800.01S 1.0 mm diameter, 750 mm, sterile 298.801.01S 1.7 mm diameter, 750 mm, sterilePredicate Device: Synthes (USA) 3.5mm / 4.5mm LCP Metaphyseal Plates Synthes (USA) Large Fragment LCP System T Plates Device Description: The Synthes 3.5mm LCP Posteromedial Proximal Tibia Plates are pre-contoured bone fixation plates intended for the treatment of fractures of the tibia. The plates are offered sterile and non-sterileGet the up-to-date synthes minor frag inventory 2023 now Retrieve Form. 4.6 out of 5. 63 votes. DocHub Reviews. 44 reviews. DocHub Reviews. 23 ratings. 15,005. 10,000,000+ 303. 100,000+ users . Here's how it works. 01. Edit your synthes small frag inventory online.Find out more on the DePuy Synthes Vet Large Fragment System for veterinary use in EMEA. It merges locking screw technology with conventional plating techniques.Inventory Control Form Titanium Locking Periarticular Plating System Some devices in this form may not have been licensed in accordance with Canadian law and may not be for sale in Canada. Please contact your sales consultant for items approved for sale in Canada. TILCKPERIPLATICF001 08/22 2 LengthengthL 418.075 75 mm 439.990418.080 80 mm6ePuy D Synthes 3.5 mm LCP® Clavicle Hook Plates Surgical Technique Lateral Clavicle Fractures 1 Position the patient Required set 105.434 Small Fragment LCP Instrument and Implant Set, with self-tapping screws or 145.434 Small Fragment LCP Instrument and Titanium Implant Set, with self-tapping screwsInventory Control Form Titanium Locking Periarticular Plating System Some devices in this form may not have been licensed in accordance with Canadian law and may not be for sale in Canada. Please contact your sales consultant for items approved for sale in Canada. TILCKPERIPLATICF001 08/22 2 LengthengthL 418.075 75 mm 439.990418.080 80 mmAR-2650CL Large Curve 8 86 mm AR-2651CL Medium Curve 8 93 mm AR-2652CL Small Curve 8 98 mm ... Fragment Screw, 2.5 mm QTY PRODUCT # LENGTH PRICE LOT# UDI AR-2665-10H 10 mm AR-2665-12H 12 mm AR-2665-14H 14 mm AR-2665-16H 16 mm ... Inventory Control Form Author: Arthrex, Inc. A-Z Ortho 917 Lone Oak Rd Eagan, MN 55121 [email protected] Call 800.524.5194 Proud to offer products made in the USA. Synforms Small Frag Inventory is a web-based inventory management system designed to help retailers and wholesalers manage their fragrances. It is a cloud-based system that allows users to track inventory, manage orders, view analytics, and receive notifications when stock levels are low. The system also includes features such as product ... Edit Synthes va distal radius inventory. Easily add and highlight text, insert images, checkmarks, and icons, drop new fillable fields, and rearrange or delete pages from your document. Get the Synthes va distal radius inventory accomplished. Download your modified document, export it to the cloud, print it from the editor, or share it with ... 6 DePuy Synthes Large Fragment LCP® Instrument and Implant Set Surgical Technique Indications The Synthes Locking Compression Plates—Narrow and broad, are intended for fixation of various long bones, such as the humerus, femur, and tibia. They are also for use in fixation of periprosthetic fractures, osteopenic bone, and 4 DePuy Synthes 4.5 mm LCP® Proximal Femur Plates Surgical Technique AO Principles In 1958, the AO formulated four basic principles, which 1 4 2 3 4_Priciples_03.pdf 1 05.07.12 12:08 4 DePuy Synthes Expert Lateral Femoral Nail Surgical Technique AO PRINCIPLES In 1958, the AO formulated four basic principles, whichLarge fragment 310.290 Drill Bit B 3.2 mm, length 195/170 mm, 2-flute, for Quick Coupling Drill with an appropriate drill bit. 6. Determine screw length Instruments Small fragment 319.010 Depth Gauge for Screws B 2.7 to 4.0 mm, measuring range up to 60 mm Large fragment 319.100 Depth Gauge for Screws B 4.5 to 6.5 mm, measuring range up to 110 mmFeatures. Specially large bends provide optimal guidance through the soft tissues. Can be used even in adipose patients. Ball tips allow a secure hold in the bone despite minimal contact. Threaded pin for secure and continu-ously adjustable locking of the for-ceps. Spiked disk that can be placed onto the tips permits use even in poor bone quality.Inventory Control Form 4.5 mm VA LCP™ Curved Condylar Plate System with OPTILINK™ Screw Technology Some devices in this form may not have been licensed in accordance with Canadian law and may not be for sale in Canada. Please contact your sales consultant for items approved for sale in Canada. Ti/VALCPCC/ICF/V2 04/22 Page 1 of 2"the same as DePuy Synthes Companies." Combining implants from other companies with DePuy Synthes Companies implants could reduce product performance. Consequently, it is strongly recommended to not mix parts from different manufacturers. 1.Test data on file at DePuy Synthes (Ref Test Report #SET_20110610)Inventory Control Form - Stainless Steel. View PDF. Inventory Control Form - Titanium. View PDF. Select all documents (2) Download Selected Items. DePuy Synthes 3.5 mm Periarticular Proximal Humerus Plates are indicated for fractures, fracture dislocations, osteotomies, and nonunions of the proximal humerus, particularly in osteopenic bone.Follow our easy steps to get your Synthes Small Frag Inventory prepared rapidly: Pick the web sample from the library. Complete all necessary information in the required fillable areas. The easy-to-use drag&drop user interface makes it easy to add or relocate areas. Make sure everything is completed appropriately, without any typos or lacking ...01. To fill out Synforms large frag inventory, begin by gathering all necessary information about the inventory items. This may include names, descriptions, quantities, and any other relevant details. 02. Make sure to have a clear understanding of the purpose of the Synforms large frag inventory and how it will be used.Fill Synthes Dhs Inventory, Edit online. Sign, fax and printable from PC, iPad, tablet or mobile with pdfFiller Instantly. Try Now!4 DePuy Synthes 4.5 mm LCP® Proximal Tibia Plates Surgical Technique AO PRINCIPLES In 1958, the AO formulated four basic principles, which 1 4 2 3 …Size-specific modules. Offering surgeons the simplicity of a comprehensive plating system that addresses all small fragment surgical needs. Additionally, this system provides color-coding of instruments and trays to match plate and screw fixation options.Inventory Control Form Large Fragment LCP™ System Some devices in this form may not have been licensed in accordance with Canadian law and may not be for sale in Canada. Please contact your sales consultant for items approved for sale in Canada. LCPLARGEFRAGICF001v2 07/22 3 Available nonsterile or sterile-packed.Get the Synthes wrist fusion inventory control form accomplished. Download your updated document, export it to the cloud, print it from the editor, or share it with others through a Shareable link or as an email attachment. ... stryker wrist fusion plate 319.01 synthes synthes small frag inventory. Related forms. 18448988542. Learn more ...EVOS SMALL Resources. Catalog excerpts. Simply advanced The EVOS SMALL Plating System takes an evolutionary approach to simplifying and unifying small fragment plating systems. www.EVOSsmall.com smith&nephew EVOS SMALL Plating System Supporting healthcare professionals. Open the catalog to page 1. Trauma surgery is challenging and ever-changing.Simply advanced. Offering surgeons the simplicity of one comprehensive plating system that addresses small fragment surgical needs. Additionally, this system provides colour-coded instruments and trays to match plate and screw fixation options.Follow our easy steps to get your Synthes Small Frag Inventory prepared rapidly: Pick the web sample from the library. Complete all necessary information in the required fillable areas. The easy-to-use drag&drop user interface makes it easy to add or relocate areas. Make sure everything is completed appropriately, without any typos or lacking ...01. To fill out Synforms large frag inventory, begin by gathering all necessary information about the inventory items. This may include names, descriptions, quantities, and any other relevant details. 02. Make sure to have a clear understanding of the purpose of the Synforms large frag inventory and how it will be used. 6 DePuy Synthes Large Fragment LCP® Instrument and Implant Set Surgical Technique Indications The Synthes Locking Compression Plates—Narrow and broad, are intended for fixation of various long bones, such as the humerus, femur, and tibia. They are also for use in fixation of periprosthetic fractures, osteopenic bone, and 4 DePuy Synthes Small Fragment Locking Compression Plate (LCP ®) System Surgical Technique. AO Principles. In 1958, the AO formulated four basic principles, which . 1 4 2 3. 4_Priciples_03.pdf 1 05.07.12 12:08. 4 DePuy Synthes Expert Lateral Femoral Nail Surgical Technique. AO PRINCIPLES. In 1958, the AO formulated four basic principles, which01. Edit your small frag inventory online. Type text, add images, blackout confidential details, add comments, highlights and more. 02. Sign it in a few clicks. Draw your signature, type it, upload its image, or use your mobile device as a …When it comes to purchasing a pre-owned vehicle, Ford is a brand that often comes to mind. Known for their reliability, performance, and wide range of models, Ford offers an impres...Unit of Measurement: Each. Catalog Number: 105.488. Set includes an assortment of instrumentation, implants, and storage. CLICK HERE for a full list of set contents. See alternate view below. Trials available. Photo is representative—please contact your sales rep for more complete details.Learn more on the 1.5 mm LCP® Modular Mini Fragment System by DePuy Synthes, with a variety of plate styles to address a range of small bone fractures.The Universal Small Fragment (USF) System is intended to be used for small bone trauma, including anatomy such as Shoulder, Clavicle, Elbow, Tibia and Fibula. The core set can …Unit of Measurement: Each. Catalog Number: 105.488. Set includes an assortment of instrumentation, implants, and storage. CLICK HERE for a full list of set contents. See alternate view below. Trials available. Photo is representative—please contact your sales rep for more complete details.Inventory Control Form - synthes.vo.llnwd.net. ImplantsDate:Hospital:Surgeon:Procedure: Case Information (eg, Case ID): Inventory Control FormSmall Fragment Locking Compression Plate (LCP ) System mm Locking Screws, self-tapping, with StarDriveTM Recess Length 54 mm 56 mm 58 mm 10 mm 12 mm 14 mm 16 mm 18 mm 20 mm 22 …increasing market shift to fragment -specific plating and using small plates as adjuncts to other means of adjunct fixation. The modular tray offers screw and plate options in 2.0 mm, 2.4 mm, and 2.7 mm. With a variety of plates to fit a multitude of trauma needs, the Mini Frag System is a keystone addition to the Arthrex Trauma lineup thatLarge Fragment System Synthes |... Inventory Control Form - J&J Medical. Devices Synthes Screw Reference Chart - Cambridge... Learn more Inventory Control Form. Inventory Control Form. Modular Mini Fragment LCP System. 2.0 mm, 2.4 mm and 2.7... Learn more Related links form. Form 1256 Gains And Losses Pdf 2013 ...Synthes (USA) Synthes (Canada) Ltd. To Order: (800) 523-0322 To Order: (800) 668-1119 Date: Hospital: Surgeon: Procedure: Implants Patient Information: J8398B 7/09 Inventory Control Form 3.7 mm Cannulated Locking and Conical Screws 3.7 mm Cannulated Locking Screws 3.7 mm Cannulated Conical Screws 02.240.210 10 mm 02.240.212 12 mm 02.240.214 14 ...AR-2650CL Large Curve 8 86 mm AR-2651CL Medium Curve 8 93 mm AR-2652CL Small Curve 8 98 mm ... Fragment Screw, 2.5 mm QTY PRODUCT # LENGTH PRICE LOT# UDI AR-2665-10H 10 mm AR-2665-12H 12 mm AR-2665-14H 14 mm AR-2665-16H 16 mm ... Inventory Control Form Author: Arthrex, Inc.Large Fragment LCP® Instrument and Implant Set Surgical Technique DePuy Synthes 1 Introduction Surgical Technique Product Information Large Fragment LCP Instrument and Implant Set 2 Locking Screws 4 AO Principles 5 Indications 6 Fixation Principles—Conventional Plating 7 Fixation Principles—Locked Plating 903.231.016. Screwdriver Shaft, hexagonal 4.0 mm, cannulated, length 180 mm, for Hexagonal Coupling 6.0 mm. Choose an aiming arm hole and make an incision through it. For off-axis insertion of VA cannulated locking screws. 5.0 mm, insert the VA wire guide 2.5 mm with spheri-cal head into the protection sleeve.Large Diameter Guide Wires • To provide more precise screw placement. Low Profile Screw Head Reverse Cutting Flute • To facilitate removal. Packaging • Implants individually sterile packaged. Features & Benefits The Asnis III Cannulated Screw System is designed to assist surgical outcomes while simplifying procedures.® 2 Mini Fragment system set overview MiniFrag: tray layout A Top Layer: VariAx 2 Instruments • T8 specific instruments (Drills, Drill Guide, Joystick, Screwdriver) • General instruments (Handle, Depth Gauge, Bending tools etc) 1 Drawer: T8 Screws & Plates • 2.7mm Screws (Locking & Non-Locking) • 2.4mm Screws (Locking & Non-Locking)PediFrag. The OP PediFrag System is a unique combination fragment set specifically designed by pediatric orthopedic surgeons for pediatric orthopedic surgery. This 3-in-1 system combines the optimal portions of mini fragment, small fragment and 4.0mm cannulated screw systems to specifically support fracture management to meet the …Customer Service, Support & Sales Tel: (574) 267-8143 or (800) 473-3789 Fax: (800) 669-2530Fill synthes small frag inventory sites instantly, Edit online. Sign, fax and printable from PC, iPad, tablet or mobile. Try Now! Home; For Business. Enterprise. Organizations. ... synthes large frag inventory. Inventory Control Form Titanium Large Fragment LCP System Patient Information: SYNTHS (USA) To Order: (800) 523-0322 SYNTHS (Canada ... SYNTHES (USA) SYNTHES (Canada) Ltd. To Order: (800) 523-0322 To Order: (800) 668-1119 Date: Hospital: Surgeon: Procedure: Implants Patient Information: J7889-C 2/12 Inventory Control Form Titanium Modular Mini Fragment LCP System 2.0 mm, 2.4 mm and 2.7 mm Instrument and Implant Modules 2.0 mm Titanium Cortex Screws, self-tapping LENGTH LENGTH ... Edit, sign, and share synthes smaller frag inventory online. No need to install software, just go to DocHub, and augury up instantly and by free. Start. Forms Library. Synthes small frag warehouse. Get the up-to-date synthes small frag record 2023 now Get Form. 4.6 outwards of 5. 63 votes. DocHub Reviews. 44 reviews. DocHub Critical.Fill Synthes Mini Frag Inventory, Edit online. Sign, fax and printable from PC, iPad, tablet or mobile with pdfFiller Instantly. Try Now! Home; For Business. ... synthes large frag inventory. Inventory Control Form Large Fragment LCP System SYNTHS (USA) To Order: (800) 5230322 Patient Information: SYNTHS (Canada) Ltd. To Order: (800) 6681119.LCP Distal Femur and LCP Proximal Lateral Tibia (LISS) Stainless Steel and Titanium. Synthes (USA) To Order: (800) 523-0322 Synthes (Canada) Ltd. To Order: (800) 668-1119.4 Surgical Technique • Large Distractor - Tibia 1 Müller ME, Allgöwer M, Schneider R, Willenegger H. Manual of Internal Fixation. 3 rd ed. Berlin, Heidelberg New York: Springer 1991. 2 Buckley RE, Moran CG, Apivatthakakul T. AO Principles of Fracture Management: 3 rd ed. Vol. 1: Principles, Vol. 2: Specific fractures.Synthes Large Fragment LCP Instrument Set (115.401) Instrumentation Catalog # Description ... 690.363 Large Fragment LCP Instrument Graphic Case 690.363.10 Base …Date: General: Surgeon: Procedure: Implants. Patient Information: J3925-L 8/12. Inventory Control Form. Locking Small Snapping LCP. 2.7 mm Cortex Screws,. Correct, signal, press shares synthes small frag inventory online. No need to install software, just go to DocHub, the token up instantly and for available.Handy tips for filling out Synthes small frag inventory online. Printing and scanning is no longer the best way to manage documents. Go digital and save time with signNow, the best solution for electronic signatures.Use its powerful functionality with a simple-to-use intuitive interface to fill out Synthes large frag inventory online, e-sign them, and quickly share them without jumping tabs.Get the Synthes Small Fragment Set Inventory Sheet you want. Open it using the cloud-based editor and start altering. Fill the blank fields; concerned parties names, addresses and numbers etc. Customize the blanks with exclusive fillable fields. Put the day/time and place your electronic signature. Click Done after double-checking all the data.

Using our solution filling exit Synthes Small Frag Lcp Inventory Control Form just takes one matter of minutes. We make that possible by offering you zugang till our full-fledged editor capable of altering/correcting a document?s original textual content, addition unique area, and putting your signature on.. Mexican restaurants new braunfels tx

synthes large frag inventory

Fill out Synthes Cannulated Screw Set Inventory Sheet within several clicks by simply following the instructions below: Choose the document template you will need from the collection of legal form samples. Click on the Get form button to open it and start editing. Submit the requested boxes (they are marked in yellow). SYNTHES (USA) SYNTHES (Canada) Ltd. To Order: (800) 523-0322 To Order: (800) 668-1119 Date: Hospital: Surgeon: Procedure: Implants Patient Information: J7889-C 2/12 Inventory Control Form Titanium Modular Mini Fragment LCP System 2.0 mm, 2.4 mm and 2.7 mm Instrument and Implant Modules 2.0 mm Titanium Cortex Screws, self-tapping LENGTH LENGTH ... B) Large fragment plates: AxSOS 3 Ti 5.0mm compression plates 5.0mm broad compression plate, 6 to 22-hole plates 5.0mm narrow compression plate, 2 to 22-hole plates AxSOS 3 Ti screws used with the AxSOS 3 Ti 5.0mm compression plates: SPS Titanium Basic Fragment ISO screws used with the AxSOS 3 Ti large fragment plates: 6.0mm cancellous 32mm threadSynthes (USA) Large Fragment LCP System T Plates Device Description: The Synthes 3.5mm LCP Posteromedial Proximal Tibia Plates are pre-contoured bone fixation plates intended for the treatment of fractures of the tibia. The plates are offered sterile and non-sterile and are available in stainless steel and titanium. ...The Mini Fragment System offers 1.5mm, 2.0mm and 2.4mm standard and 2.0mm and 2.4mm locking implants and instruments. Limited‐contact plate design Reduces plate‐to bone contact, protecting vascularityUniversal Small Fragment System System Catalog DePuy Synthes 2 Instruments Core System Trays Anatomic Implant Trays Case & Lid Options Set Information Table of Contents Case & Lid Options 40 Graphics Cases 41 Tray Lids 42 Set Information 43 Summary of Set ListsCore System Trays 442 DePuy Synthes Small Fragment Locking Compression Plate (LCP ®) System Surgical Technique 223.581 241.981. Small Fragment Locking Compression Plate (LCP ®) System. The aim of any surgical fracture treatment is to reconstruct the anatomy and restore its function. According to the AO, internal fixation is distinguishedIn February, active inventory rose 68% above a year ago; Austin, Las Vegas and San Antonio are first markets to recover pandemic inventory shortag... In February, active inventory ...Universal Small Fragment System supports insertion of any DePuy Synthes 2.7 mm or 3.5 mm . non-locking LCP ® or VA LCP ® Implant Technology* *pecialized instrumentation used for implants above may be needed. Implants shown above may not be available in all markets.S Contact your local DePuy Synthes representative for more information ...Manage synthes large cchs inventory on any device with airSlate SignNow Android or iOS apps and elevate any document-centered operation today. How to change and eSign synthes non locking small frag inventory without breaking a sweat. Get synthes small cchs and click Get Form to get started.Large External Fixator—Delta Frame Ankle Bridge Surgical Technique DePuy Synthes 5 RECOMMENDED COMPONENTS FOR BASIC FRAME ProductItem Quantity Number Needed 293.xx 5.0 mm Steinmann Pin, 1 with central thread 294.78x 5.0 mm Self-Drilling 2 Schanz Screw 390.005 Large Combination 2 Clamp 390.008 Large Open Adjustable 2 ClampGet the Synthes Small Fragment Set Inventory Sheet you want. Open it using the cloud-based editor and start altering. Fill the blank fields; concerned parties names, addresses and numbers etc. Customize the blanks with exclusive fillable fields. Put the day/time and place your electronic signature. Click Done after double-checking all the data.top with large stop, 150 mm Sizing Template Set 03.111.121S Sizing Template Set for 2.4/2.7 mm VA LCP Two-Column Volar Distal Radius Plate, Extra-long, Sterile Synthes USA, LLC 1101 Synthes Avenue Monument, CO 80132 Manufactured or distributed by: Synthes USA Products, LLC 1302 Wrights Lane East West Chester, PA 19380 To order (USA): 800-523-0322Make these fast steps to modify the PDF Synthes small frag inventory online free of charge: Register and log in to your account. Log in to the editor with your credentials or click on Create free account to evaluate the tool's functionality. Add the Synthes small frag inventory for redacting. Click the New Document button above, then drag and ... The Small Fragment LCP™ System features: Plates with combination locking and compression holes (Combi holes) Ability to create a fixed-angle construct utilizing familiar AO plating techniques. Screws with conical screwhead and large core diameter. Get in Touch with a Sales Consultant. Large fragment 310.290 Drill Bit B 3.2 mm, length 195/170 mm, 2-flute, for Quick Coupling Drill with an appropriate drill bit. 6. Determine screw length Instruments Small fragment 319.010 Depth Gauge for Screws B 2.7 to 4.0 mm, measuring range up to 60 mm Large fragment 319.100 Depth Gauge for Screws B 4.5 to 6.5 mm, measuring range up to 110 mm .

Popular Topics